Heidelberg Replacement Infrared Lamps
Independently manufactured replacement infrared lamps for Heidelberg Speedmaster and DryStar-related drying systems. Start with an original part number, machine model, existing lamp, drawing or clear photographs.
Search Common Speedmaster & DryStar Lamp References
Use the part number as the starting point, then reconfirm the installed lamp dimensions and electrical specification before production.
Send photographs of the complete lamp, both ceramic ends, printed markings and measured overall length. A machine model or dryer reference is also useful.
| Machine / System | Part No. | Voltage | Wattage | OAL | Construction Reference |
|---|---|---|---|---|---|
| Speedmaster 74 | M6.170.0301/01 | 400 V | 6950 W | 900 mm | Twin tube, gold reflector |
| Speedmaster 74 | SM74-FMW-B | 480 V | 4200 W | 900 mm | Twin-tube reference |
| Speedmaster 52 | G4.170.0101 | 415 V | 3300 W | 740 mm | Twin tube, gold reflector |
| M Offset / MO | 53.170.1311 | 415 V | 3300 W | 740 mm | Twin tube, gold reflector |
| Speedmaster 102 | 91.170.1311 | 415 V | 3500 W | 1100 mm | Twin-tube dryer emitter |
| Speedmaster 102 | C7.170.0301/01 | 400 V | 5400 W | 1200 mm | Twin-tube reference |
| Speedmaster 102 | 91.170.1411 | 415 V | 2500 W | 1100 mm | Twin tube, gold reflector |
| Speedmaster 102 | SM102-FMW-B | 480 V | 6000 W | 1125 mm | Twin-tube reference |
| Speedmaster 102 | F7.170.0771 | 400 V | 6200 W | 1160 mm | 33 × 15 mm twin tube |
| Speedmaster 72 | 83.170.1311 | 415 V | 3500 W | 800 mm | Twin tube, gold reflector |
| Speedmaster 72 | 83.170.1411 | 415 V | 1900 W | 800 mm | Twin tube, gold reflector |
| XL105 | F7.170.0771.01 | 400 V | 6200 W | 1160 mm | 33 × 15 mm twin tube |
Reference data should be reconfirmed against the existing lamp, equipment version and installation details before production.
A Heidelberg Dryer Lamp Must Match More Than the Part Number
Printing dryer systems can use similar-looking lamps with different electrical ratings, quartz profiles, heated zones, reflector positions or end connections. These details should be checked before a replacement is produced.
Overall & Heated Length
Confirm total lamp length, active heated length, cold ends and any divided heating zones.
Twin-Tube Profile
Check the quartz cross-section, including standard and larger twin-tube constructions.
Reflector Position
Reflector material, coverage and direction affect where infrared energy is directed.
Ceramic Ends & Wiring
Terminal shape, ceramic blocks, lead wires and orientation must suit the existing installation.
Real Twin-Tube Infrared Lamp Configurations
Product photographs from our infrared lamp range show reflector, quartz profile, terminal and construction variations relevant to printing dryer replacement projects.
91.170.1411 Reference
Twin-tube lamp reference with directional reflector for Speedmaster-related dryer applications.
6200W Twin-Tube Lamp
High-power twin-tube construction used as a reference for long-format printing dryer applications.
White Reflector Option
White reflector construction for selected infrared heating and drying requirements.
Dimensional Matching
Existing lamp samples and drawings can be used to compare dimensions and mounting details.
Popular Speedmaster Replacement Lamp References
Individual part-number pages provide a more focused reference for buyers who already know the lamp number.
91.170.1311 — Speedmaster 102
Twin-tube replacement reference for Speedmaster 102 printing dryer applications.
91.170.1411 — Speedmaster 102
Twin-tube infrared lamp reference with gold reflector for Speedmaster-related dryer systems.
M6.170.0301/01 — Speedmaster 74
High-power twin-tube infrared lamp reference for Speedmaster 74 drying equipment.
F7.170.0771 — SM102 / XL105
Larger twin-tube construction used as a reference for high-power printing dryer applications.
C7.170.0301/01 — Speedmaster 102
Long twin-tube infrared lamp reference for Speedmaster 102 dryer systems.
G4.170.0101 — Speedmaster 52
Twin-tube infrared lamp reference associated with Speedmaster 52 and related printing dryer systems.
Information for a Heidelberg Replacement Lamp Review
A part number is useful, but the existing lamp should still be checked when possible.
- Heidelberg part number or Speedmaster machine model
- Voltage and wattage shown on the old lamp
- Complete overall length and heated length
- Twin-tube quartz cross-section
- Reflector type, coverage and direction
- Photographs of both ceramic end fittings
- Lead-wire length, terminals and mounting details
- Required prototype and repeat quantity
From Part Number to Confirmed Replacement Lamp
Each project should confirm the important electrical, dimensional and installation details before production.
Submit the Reference
Send the Heidelberg part number, machine model, old lamp photographs, drawing or physical sample.
Compare the Installed Lamp
Check voltage, wattage, dimensions, quartz profile, reflector, terminals and wiring.
Confirm the Proposed Specification
The proposed construction, price, quantity and production details are confirmed before sampling.
Prototype & Machine Evaluation
Sample production can be discussed for installation and equipment testing before repeat supply.
Repeat Supply
The approved specification can be retained as the reference for future repeat orders.
Young Light Technology supplies independently manufactured replacement infrared heating lamps. Heidelberg, Speedmaster, DryStar and referenced part numbers are used only to identify intended equipment compatibility and replacement requirements. Young Light Technology is not affiliated with, sponsored by or endorsed by Heidelberger Druckmaschinen AG.
Common Questions About Heidelberg Infrared Lamps
Can you review a replacement using only a Heidelberg part number?
Yes. A known part number can be used as the starting reference. The installed lamp voltage, overall length and construction should still be reconfirmed where possible.
What if the original lamp number can no longer be read?
Send clear photographs of the complete lamp, both ceramic ends, printed markings and measured length. The Speedmaster machine model or dryer-system information is also helpful.
Are Young Light Heidelberg replacement lamps original Heidelberg products?
No. They are independently manufactured replacement infrared lamps. Heidelberg names and part numbers are used only as equipment and compatibility references.
Can you produce a sample before I order a full dryer set?
Prototype production can be discussed after the lamp specification, construction, quantity and commercial terms have been confirmed.
Why do you need photographs if I already have the part number?
Existing equipment may have different dryer versions, previous replacement lamps or modified terminals. Photographs help confirm the actual lamp installed in the machine.
What details are most important for a twin-tube dryer lamp?
Important details include voltage, wattage, overall length, heated length, quartz cross-section, reflector direction, heating-zone arrangement, ceramic ends, lead wires and operating position.